drivers: edac: Make ecc polling configurable
ECC can work both in polling and interrupt mode. Add config option to enable polling mode. Change-Id: I99668a143ecbd70a3a4f713f89268df64bfca2da drivers: edac: Configure the interrupt as level triggered As per the interrupt maps the ecc interrupt for llcc is level triggered. Update the irq request call to pass the right trigger. Change-Id: I029ca8fcf5207d2dffdb13ebc627c64811cf196a edac: llcc: Add NULL pointer check and fix data types Add NULL pointer check to make sure edac device is allocated properly, pass nr_blocks as 0 to edac alloc control device api since the block_name is null in case of llcc and change the data type of llcc_banks to u32 instead of phys_addr_t. Change-Id: I52a0d33a0d546db235751104cd225c29f79f5356 drivers: edac: Update banks for edac sysfs entry Pass the number of banks and bank name to edac framework to have sysfs nodes created for each llcc bank for reading out the ce/ue error counts. Add edac device before registering for interrupt, as the interrupt handler uses edac device for interrupt processing and would result into crash if there is any ecc error immidiately after registering the interrupt and before adding the edac device. Change-Id: I2c36458684feaf68a63203f871df91f862354e6a Signed-off-by:Channagoud Kadabi <ckadabi@codeaurora.org> Signed-off-by:
Prasad Sodagudi <psodagud@codeaurora.org>
Loading