sf: Fixes for resolution change in SurfaceFlinger
1. Use active config from HWC when querying display attributes When we query the display attributes we should use the active config as reported by HWC in cases where HWC version is 1.4. In all other cases we should revert to the default config, config 0, as the active config. 2. Set/update the display config if HWC config change was successful The new config should only be applied if HWC succeeded in changing the active config. This would otherwise cause failure or undefined behavior if the client sets an invalid/unsupported display config. 3. Set the active config at display creation time When a new display device is added update the active config by querying HWC. Change-Id: If55b9b308750f17bb44eab555d17e31972bc3968