Remove internal display related methods
SurfaceFlinger and SurfaceComposerClient simply return the first connected display as internal display, which is not really correct. In particular,in the case of dual display for foldable devices, both displays are marked as Internal determined by calling into HWC2 IComposerClient::getDisplayConnectionType(). Therefore, the concept of internal/external/primary displays is removed from SurfaceFlinger, and the display manager is the better place to handle the logics. flatland is modified to take an extra argument to specify display id, and error occurs if no display is specified in case of multi-display. Bug: 241285477 Bug: 242763577 Bug: 74619554 Test: atest libgui_test libsurfaceflinger_unittest SurfaceFlinger_test Change-Id: Ib6c7e502ef3269c2c60a4e5388e5ac75275f87ed