cameraservice: Resolve message vs start/stop preview races
Move the mutex in start/stopPreview to include the metadata message management. Fast start/stop sequences could (and would) eventually cause the messages to be enabled/disabled out of sequence (or while the camera wasn't ready for it) Fixes BACON-173 Change-Id: I367bc45729ce2e858fea972f35e881a755c6021a