Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Skip to content
Commit bd090374 authored by Thomas Petazzoni's avatar Thomas Petazzoni Committed by Greg Kroah-Hartman
Browse files

spi: orion: fix incorrect handling of cell-index DT property



commit e06871cd2c92e5c65d7ca1d32866b4ca5dd4ac30 upstream.

In commit f814f9ac ("spi/orion: add device tree binding"), Device
Tree support was added to the spi-orion driver. However, this commit
reads the "cell-index" property, without taking into account the fact
that DT properties are big-endian encoded.

Since most of the platforms using spi-orion with DT have apparently
not used anything but cell-index = <0>, the problem was not
visible. But as soon as one starts using cell-index = <1>, the problem
becomes clearly visible, as the master->bus_num gets a wrong value
(actually it gets the value 0, which conflicts with the first bus that
has cell-index = <0>).

This commit fixes that by using of_property_read_u32() to read the
property value, which does the appropriate endianness conversion when
needed.

Fixes: f814f9ac ("spi/orion: add device tree binding")
Signed-off-by: default avatarThomas Petazzoni <thomas.petazzoni@free-electrons.com>
Acked-by: default avatarSebastian Hesselbarth <sebastian.hesselbarth@gmail.com>
Signed-off-by: default avatarMark Brown <broonie@linaro.org>
Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@linuxfoundation.org>
parent b15dba93