power: smb1360: Add a property to disable ov-ends-chg-cycle
With ov-ends-charge-cycle enabled, if soft JEITA kicks in and battery voltage higher than compensated float voltage, the battery OV(over voltage) interrupt will be triggered and charging will be stopped. After battery temperature falls back to normal range, charging won't be resumed automatically until charging disabled/enabled once. Add the interface to disable ov-ends-charge-cycle, to fix charging can not resume issue. CRs-Fixed: 854879 Change-Id: I07abe0b25f4d389154afaa83495e2c42d37c5029 Signed-off-by:Zhenhua Huang <zhenhuah@codeaurora.org> Signed-off-by:
Ashay Jaiswal <ashayj@codeaurora.org>