ASoC: WCD9304: Fix threshold value for class G headphone



When playing a full scale tone with highest gain in the codec, OCP
(Over Current Protection) event is generated. This is caused due to
lower switching frequency for the class G amplifier on headphone
path. Fix the false OCP event trigger by appropriately setting the
class G switching frequency

CRs-fixed: 406641
Change-Id: I9563ab2d06c970b47693293175fe7ae4a711348c
Signed-off-by: default avatarBhalchandra Gajare <gajare@codeaurora.org>