hwmon: (lm90) Fix max6696 alarm handling



commit e41fae2b1ed8c78283d73651cd65be0228c0dd1c upstream.

Bit 2 of status register 2 on MAX6696 (external diode 2 open)
sets ALERT; the bit thus has to be listed in alert_alarms.
Also display a message in the alert handler if the condition
is encountered.

Even though not all overtemperature conditions cause ALERT
to be set, we should not ignore them in the alert handler.
Display messages for all out-of-range conditions.

Reported-by: default avatarJean Delvare <khali@linux-fr.org>
Signed-off-by: default avatarGuenter Roeck <linux@roeck-us.net>
Signed-off-by: default avatarJean Delvare <khali@linux-fr.org>
Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@linuxfoundation.org>