Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Commit a28caa7b authored by Maciej Purski's avatar Maciej Purski Committed by Greg Kroah-Hartman
Browse files

iio: adc: ina2xx: Make calibration register value fixed

Calibration register is used for calculating current register in
hardware according to datasheet:
current = shunt_volt * calib_register / 2048 (ina 226)
current = shunt_volt * calib_register / 4096 (ina 219)

Fix calib_register value to 2048 for ina226 and 4096 for ina 219 in
order to avoid truncation error and provide best precision allowed
by shunt_voltage measurement. Make current scale value follow changes
of shunt_resistor from sysfs as calib_register value is now fixed.

Power_lsb value should also follow shunt_resistor changes as stated in
datasheet:
power_lsb = 25 * current_lsb (ina 226)
power_lsb = 20 * current_lsb (ina 219)

This is a part of the patchset: https://lkml.org/lkml/2017/11/22/394



Signed-off-by: default avatarMaciej Purski <m.purski@samsung.com>
Reviewed-by: default avatarStefan Brüns <stefan.bruens@rwth-aachen.de>
Signed-off-by: default avatarJonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@linuxfoundation.org>
parent bbdcbd12