thermal: exynos: Reading temperature makes sense only when TMU is turned on



commit 88fc6f73fddf64eb507b04f7b2bd01d7291db514 upstream.

When thermal sensor is not yet enabled, reading temperature might return
random value. This might even result in stopping system booting when such
temperature is higher than the critical value. Fix this by checking if TMU
has been actually enabled before reading the temperature.

This change fixes booting of Exynos4210-based board with TMU enabled (for
example Samsung Trats board), which was broken since v4.4 kernel release.

Signed-off-by: default avatarMarek Szyprowski <m.szyprowski@samsung.com>
Fixes: 9e4249b4 ("thermal: exynos: Fix first temperature read after registering sensor")
CC: stable@vger.kernel.org # v4.6+
Signed-off-by: default avatarBartlomiej Zolnierkiewicz <b.zolnierkie@samsung.com>
Signed-off-by: default avatarEduardo Valentin <edubezval@gmail.com>
Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@linuxfoundation.org>