Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Commit 9c9a5513 authored by Linux Build Service Account's avatar Linux Build Service Account Committed by Gerrit - the friendly Code Review server
Browse files

Merge "ARM: dts: msm: specify APCC CPR rev 2-7 margin adjustments for msm8996v3"

parents 01e07424 b5a5817b
Loading
Loading
Loading
Loading
+52 −4
Original line number Diff line number Diff line
@@ -596,7 +596,7 @@

				qcom,cpr-pd-bypass-mask = <0x07>;
				qcom,cpr-fuse-corners = <5>;
				qcom,cpr-fuse-combos = <2>;
				qcom,cpr-fuse-combos = <8>;
				qcom,cpr-corners = <16>;

				qcom,ldo-headroom-voltage = <150000>;
@@ -641,9 +641,21 @@
				       2519 2257 2668 2372    0    0    0    0>;

				qcom,cpr-open-loop-voltage-fuse-adjustment =
					<0 0 (-10000) (-25000) (-25000)>,
					<0 0 (-10000) (-25000) (-25000)>,
					<0 0 0 0 0>,
					<0 0 0 0 0>,
					<0 0 0 0 0>,
					<0 0 0 0 0>,
					<0 0 0 0 0>,
					<0 0 0 0 0>;
				qcom,cpr-closed-loop-voltage-fuse-adjustment =
					<0 0 0 0 0>,
					<0 0 0 0 0>,
					<0 0 0 0 0>,
					<0 0 0 0 0>,
					<0 0 0 0 0>,
					<0 0 0 0 0>,
					<0 0 0 0 0>,
					<0 0 0 0 0>;

@@ -659,7 +671,7 @@

				qcom,cpr-pd-bypass-mask = <0x18>;
				qcom,cpr-fuse-corners = <5>;
				qcom,cpr-fuse-combos = <2>;
				qcom,cpr-fuse-combos = <8>;
				qcom,cpr-corners = <19>;

				qcom,cpr-corner-fmax-map = <1 2 5 13 19>;
@@ -702,9 +714,21 @@
				       2519 2257 2668 2372    0    0    0    0>;

				qcom,cpr-open-loop-voltage-fuse-adjustment =
					<0 0 (-45000) (-20000) (-45000)>,
					<0 0 (-45000) (-20000) (-45000)>,
					<0 0 0 0 0>,
					<0 0 0 0 0>,
					<0 0 0 0 0>,
					<0 0 0 0 0>,
					<0 0 0 0 0>,
					<0 0 0 0 0>;
				qcom,cpr-closed-loop-voltage-fuse-adjustment =
					<0 0 0 0 0>,
					<0 0 0 0 0>,
					<0 0 0 0 0>,
					<0 0 0 0 0>,
					<0 0 0 0 0>,
					<0 0 0 0 0>,
					<0 0 0 0 0>,
					<0 0 0 0 0>;

@@ -728,7 +752,7 @@

				qcom,cpr-pd-bypass-mask = <0xe0>;
				qcom,cpr-fuse-corners = <5>;
				qcom,cpr-fuse-combos = <2>;
				qcom,cpr-fuse-combos = <8>;
				qcom,cpr-corners = <25>;

				qcom,ldo-headroom-voltage = <150000>;
@@ -779,9 +803,21 @@
				       2519 2257 2668 2372    0    0    0    0>;

				qcom,cpr-open-loop-voltage-fuse-adjustment =
					<0 0 0 (-65000) (-20000)>,
					<0 0 0 (-65000) (-20000)>,
					<0 0 0 0 0>,
					<0 0 0 0 0>,
					<0 0 0 0 0>,
					<0 0 0 0 0>,
					<0 0 0 0 0>,
					<0 0 0 0 0>;
				qcom,cpr-closed-loop-voltage-fuse-adjustment =
					<0 0 0 0 0>,
					<0 0 0 0 0>,
					<0 0 0 0 0>,
					<0 0 0 0 0>,
					<0 0 0 0 0>,
					<0 0 0 0 0>,
					<0 0 0 0 0>,
					<0 0 0 0 0>;

@@ -829,7 +865,7 @@
				regulator-max-microvolt = <8>;

				qcom,cpr-fuse-corners = <4>;
				qcom,cpr-fuse-combos = <2>;
				qcom,cpr-fuse-combos = <8>;
				qcom,cpr-corners = <8>;

				qcom,cpr-corner-fmax-map = <2 4 6 8>;
@@ -884,8 +920,20 @@

				qcom,cpr-open-loop-voltage-fuse-adjustment =
					<30000 30000 30000 0>,
					<0 0 0 0>,
					<0 0 0 0>,
					<0 0 0 0>,
					<0 0 0 0>,
					<0 0 0 0>,
					<0 0 0 0>,
					<0 0 0 0>;
				qcom,cpr-closed-loop-voltage-adjustment =
					<0 30000 30000 30000 30000 30000 0 0>,
					<0 30000 30000 30000 30000 30000 0 0>,
					<0 30000 30000 30000 30000 30000 0 0>,
					<0 30000 30000 30000 30000 30000 0 0>,
					<0 30000 30000 30000 30000 30000 0 0>,
					<0 30000 30000 30000 30000 30000 0 0>,
					<0 30000 30000 30000 30000 30000 0 0>,
					<0 30000 30000 30000 30000 30000 0 0>;
				qcom,cpr-floor-to-ceiling-max-range =
+13 −1
Original line number Diff line number Diff line
@@ -31,7 +31,7 @@
	regulator-max-microvolt = <7>;

	qcom,cpr-fuse-corners = <4>;
	qcom,cpr-fuse-combos = <2>;
	qcom,cpr-fuse-combos = <8>;
	qcom,cpr-corners = <7>;

	qcom,cpr-corner-fmax-map = <2 3 5 7>;
@@ -83,8 +83,20 @@

	qcom,cpr-open-loop-voltage-fuse-adjustment =
		<30000 30000 30000 0>,
		<0 0 0 0>,
		<0 0 0 0>,
		<0 0 0 0>,
		<0 0 0 0>,
		<0 0 0 0>,
		<0 0 0 0>,
		<0 0 0 0>;
	qcom,cpr-closed-loop-voltage-adjustment =
		<0 30000 30000 30000 30000 0 0>,
		<0 30000 30000 30000 30000 0 0>,
		<0 30000 30000 30000 30000 0 0>,
		<0 30000 30000 30000 30000 0 0>,
		<0 30000 30000 30000 30000 0 0>,
		<0 30000 30000 30000 30000 0 0>,
		<0 30000 30000 30000 30000 0 0>,
		<0 30000 30000 30000 30000 0 0>;
	qcom,cpr-floor-to-ceiling-max-range =