msm: vidc: Do not halt axi after subsystem_put
Avoid any Venus register read or write after subsystem_put.
Without this patch we occasionally see AHB timeout and device
crash while trying to read the halt axi register after unloading
the firmware.
Change-Id: I5105e3f6bd37d6c12d256a35c9558c1ac6f4028c