Commit 33e5b222 authored by Werner Almesberger's avatar Werner Almesberger Committed by Jaroslav Kysela
Browse files

[ALSA] soc - Fix s3c24xx-i2s LR sync while timer ticks are disabled



When timer ticks are disabled when calling
sound/soc/s3c24xx/s3c24xx-i2s.c:s3c24xx_snd_lrsync
and the LR signal never happens, we loop forever.
This has been observed in the following call chain:
snd_pcm_common_ioctl1 -> snd_pcm_action_lock_irq ->
snd_pcm_action_single
 -> snd_pcm_do_resume -> soc_pcm_trigger -> s3c24xx_i2s_trigger

The patch below changes the timeout mechanism to use udelay, which
doesn't need timer ticks.

Signed-off-by: default avatarWerner Almesberger <werner@openmoko.org>
Signed-off-by: default avatarMark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: default avatarTakashi Iwai <tiwai@suse.de>
Signed-off-by: default avatarJaroslav Kysela <perex@perex.cz>