qpnp-fg-gen3: Fix adjusting recharge_soc after charge termination
After charge termination, recharge SOC might get adjusted, which
is fine. However, if the charger is not removed after charge
termination and SOC drops further down because of a system load,
recharge SOC should not get adjusted again. This can cause
recharging not to begin at the intended SOC threshold. Fix this.
CRs-Fixed: 2018737
Change-Id: I3595c313f84b2ea8c0459c30f294deb8ac4d2866