msm: clock-9630: Change halt_check type for pipe clocks
The usb and pcie pipe PHY hardware is not compatible with the branch
clock on/off status check. If a downstream clock is disabled before
the PHY hardware, the PHY hardware disable sequence will fail. If the
downstream clock is disabled after the PHY, the on/off status check
will fail. Therefore, remove this check for these specific clocks.
Change-Id: I3e5edfe598e43d707041d3f271c53f3a86b6fb77