[SCSI] aic7xxx: reset handler selects a wrong command



To transport scsi reset command to device aic7xxx reset handler looks
at the driver's pending_list and searches any proper command. However
the search condition has been inverted: ahc_match_scb() returns TRUE
if a matched command is found. As a result the reset on required
devices did not turn out well, a correctly working neighbour device
may be surprised by the reset. aic7xxx reset handler reports about the
success, but really the original situation is not corrected yet.

Signed-off-by: default avatarVasily Averin <vvs@sw.ru>

Naturally, there's a corresponding problem in the aic79xx driver, so
I've also added the same fix for that.

Signed-off-by: default avatarJames Bottomley <James.Bottomley@SteelEye.com>