mtip32xx: Fix to make lba address correct in big-endian systems



Earlier lba address was assigned directly to lba_low and lba_low_ex,
which would result in a different number (bytes reversed) in
big-endian systems. Now assigning lba address byte-by-byte to fis.

Reported-by: default avatarDan Carpenter <dan.carpenter@oracle.com>
Signed-off-by: default avatarSelvan Mani <smani@micron.com>
Signed-off-by: default avatarAsai Thambi S P <asamymuthupa@micron.com>
Signed-off-by: default avatarJens Axboe <axboe@kernel.dk>
parent 3208795e
Loading
Loading
Loading
Loading
+6 −2
Original line number Diff line number Diff line
@@ -2465,8 +2465,12 @@ static void mtip_hw_submit_io(struct driver_data *dd, sector_t start,
	fis->opts        = 1 << 7;
	fis->command     =
		(dir == READ ? ATA_CMD_FPDMA_READ : ATA_CMD_FPDMA_WRITE);
	*((unsigned int *) &fis->lba_low) = (start & 0xFFFFFF);
	*((unsigned int *) &fis->lba_low_ex) = ((start >> 24) & 0xFFFFFF);
	fis->lba_low     = start & 0xFF;
	fis->lba_mid     = (start >> 8) & 0xFF;
	fis->lba_hi      = (start >> 16) & 0xFF;
	fis->lba_low_ex  = (start >> 24) & 0xFF;
	fis->lba_mid_ex  = (start >> 32) & 0xFF;
	fis->lba_hi_ex   = (start >> 40) & 0xFF;
	fis->device	 = 1 << 6;
	fis->features    = nsect & 0xFF;
	fis->features_ex = (nsect >> 8) & 0xFF;