[FP5-1322] [REQ][Charging]DUT not show warning messages when battery...
[FP5-1322] [REQ][Charging]DUT not show warning messages when battery temperature is too high or too low * Root Cause Upper layer need not match the real jeita setting * Solution Report to upper layer remapped health * Test Steps 1 Put the phone to temperature chamber 2 Adjust chamber temperature to 75 degree 3 Check the battery temp and health value in the log 4 when the temp reach to 55 degree, health report 3, a pop show the high temp 5 when the temp reach to 60 degree, health report 3, a pop show the shutdown hint and then phone power off 6 Adjust chamber temperature to -40 degree 7 when the temp reach to 5 degree, healthd report 7, a pop show the low temp 8 when the temp reach to -20 degree, healthd report 7, the phone power off without pop show * Test Result Driver set pass, upper layer need check no pop issue when reach -20 degree power off Change-Id: Ibed0d7ec22fb1483d8dba46c5dd95883c9669aa8