msm: camera: isp: Handle RUP in applied substate
In TFE top-half handler, TOP register status is read first and
then based on top register status, bus register status is read.
There could be a corner case where bufdone irq top-half handling
is ongoing, top status registers are read, and while reading bus
register status we might have got SOF and RUP irqs. Since RUP and
Bufdone both come from bus side, RUP bit is set during this bus
register read. Hence, RUP is handled first along with bufdone and
then SOF irq is handled. There is no handling in statemachine for
such RUP's in RDI only context statemachine. Hence leading to
bubble condition resulting in frame drop
To overcome such scenario, handling for RUP in applied substate
is introduced in RDI only statemachine.