Commit 8227199c authored by Edwin Peer's avatar Edwin Peer Committed by Greg Kroah-Hartman
Browse files

bnxt_en: fix HWRM error when querying VF temperature



[ Upstream commit 12cce90b934bf2b0ed9c339b4d5503e69954351a ]

Firmware returns RESOURCE_ACCESS_DENIED for HWRM_TEMP_MONITORY_QUERY for
VFs. This produces unpleasing error messages in the log when temp1_input
is queried via the hwmon sysfs interface from a VF.

The error is harmless and expected, so silence it and return unknown as
the value. Since the device temperature is not particularly sensitive
information, provide flexibility to change this policy in future by
silencing the error rather than avoiding the HWRM call entirely for VFs.

Fixes: cde49a42 ("bnxt_en: Add hwmon sysfs support to read temperature")
Cc: Marc Smith <msmith626@gmail.com>
Reported-by: default avatarMarc Smith <msmith626@gmail.com>
Signed-off-by: default avatarEdwin Peer <edwin.peer@broadcom.com>
Signed-off-by: default avatarMichael Chan <michael.chan@broadcom.com>
Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>
Signed-off-by: default avatarSasha Levin <sashal@kernel.org>