x86/hpet: Simplify counter validation



There is no point to loop for 200k TSC cycles to check afterwards whether
the HPET counter is working. Read the counter inside of the loop and break
out when the counter value changed.

Signed-off-by: default avatarThomas Gleixner <tglx@linutronix.de>
Reviewed-by: default avatarIngo Molnar <mingo@kernel.org>
Cc: Peter Zijlstra <peterz@infradead.org>
Cc: Ricardo Neri <ricardo.neri-calderon@linux.intel.com>
Cc: Ashok Raj <ashok.raj@intel.com>
Cc: Andi Kleen <andi.kleen@intel.com>
Cc: Suravee Suthikulpanit <Suravee.Suthikulpanit@amd.com>
Cc: Stephane Eranian <eranian@google.com>
Cc: Ravi Shankar <ravi.v.shankar@intel.com>
Link: https://lkml.kernel.org/r/20190623132435.149535103@linutronix.de