Don't abort clock initialization if we cannot match an entry in tegra_clk_init_table to a valid entry in the clk array. Also log a corresponding error message. This was discovered when testing a patch that removed the EMC clock from tegra124_clks but left a mention in tegra_clk_init_table. Signed-off-by:Tomeu Vizoso <tomeu.vizoso@collabora.com> Reviewed-by:
Stephen Warren <swarren@nvidia.com>