power: qpnp-fg-gen3: adjust recharge voltage during soft JEITA charge done
When there is an early charge termination because of soft JEITA
(warm and cool) conditions, float voltage would have been reduced
by the charger based on the compensation configuration (e.g. by
105 mV). This can be close to the recharge voltage threshold
(e.g. 4.25 V) when the recharge is configured to be based off
Vbatt. Adjust the recharge voltage threshold dynamically by
lowering it by 200 mV during soft JEITA and charge termination.
Reset it back to the original value when the condition clears
i.e. either it is out of soft JEITA or the charger is removed.
Change-Id: If4d293c10e84e414c81204784f2e7062140264b1
Signed-off-by:
Subbaraman Narayanamurthy <subbaram@codeaurora.org>