olpc_battery: Add support for CHARGE_FULL_DESIGN



Some user space software (read: UPower) uses CHARGE_FULL_DESIGN for internal
calculations. The design capacity of the OLPC batteries is effectively fixed
and only needs to be exported.

Signed-off-by: default avatarSascha Silbe <sascha-pgp@silbe.org>
Signed-off-by: default avatarPaul Fox <pgf@laptop.org>
Signed-off-by: default avatarAnton Vorontsov <cbouatmailru@gmail.com>
parent c566d299
Loading
Loading
Loading
Loading
+54 −0
Original line number Diff line number Diff line
@@ -201,6 +201,54 @@ static int olpc_bat_get_tech(union power_supply_propval *val)
	return ret;
}

static int olpc_bat_get_charge_full_design(union power_supply_propval *val)
{
	uint8_t ec_byte;
	union power_supply_propval tech;
	int ret, mfr;

	ret = olpc_bat_get_tech(&tech);
	if (ret)
		return ret;

	ec_byte = BAT_ADDR_MFR_TYPE;
	ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1);
	if (ret)
		return ret;

	mfr = ec_byte >> 4;

	switch (tech.intval) {
	case POWER_SUPPLY_TECHNOLOGY_NiMH:
		switch (mfr) {
		case 1: /* Gold Peak */
			val->intval = 3000000*.8;
			break;
		default:
			return -EIO;
		}
		break;

	case POWER_SUPPLY_TECHNOLOGY_LiFe:
		switch (mfr) {
		case 1: /* Gold Peak */
			val->intval = 2800000;
			break;
		case 2: /* BYD */
			val->intval = 3100000;
			break;
		default:
			return -EIO;
		}
		break;

	default:
		return -EIO;
	}

	return ret;
}

/*********************************************************************
 *		Battery properties
 *********************************************************************/
@@ -294,6 +342,11 @@ static int olpc_bat_get_property(struct power_supply *psy,
		else
			val->intval = POWER_SUPPLY_CAPACITY_LEVEL_NORMAL;
		break;
	case POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN:
		ret = olpc_bat_get_charge_full_design(val);
		if (ret)
			return ret;
		break;
	case POWER_SUPPLY_PROP_TEMP:
		ret = olpc_ec_cmd(EC_BAT_TEMP, NULL, 0, (void *)&ec_word, 2);
		if (ret)
@@ -341,6 +394,7 @@ static enum power_supply_property olpc_xo1_bat_props[] = {
	POWER_SUPPLY_PROP_CURRENT_AVG,
	POWER_SUPPLY_PROP_CAPACITY,
	POWER_SUPPLY_PROP_CAPACITY_LEVEL,
	POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN,
	POWER_SUPPLY_PROP_TEMP,
	POWER_SUPPLY_PROP_TEMP_AMBIENT,
	POWER_SUPPLY_PROP_MANUFACTURER,