Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Commit c566d299 authored by Daniel Drake's avatar Daniel Drake Committed by Anton Vorontsov
Browse files

olpc_battery: Ambient temperature is not available on XO-1.5



The XO-1.5 does not support the ambient temperature property.
Create a separate list of properties for that configuration where
ambient temperature is not included, and apply the correct property
list at runtime.

Signed-off-by: default avatarDaniel Drake <dsd@laptop.org>
Signed-off-by: default avatarAnton Vorontsov <cbouatmailru@gmail.com>
parent f3dcab70
Loading
Loading
Loading
Loading
+25 −3
Original line number Diff line number Diff line
@@ -331,7 +331,7 @@ static int olpc_bat_get_property(struct power_supply *psy,
	return ret;
}

static enum power_supply_property olpc_bat_props[] = {
static enum power_supply_property olpc_xo1_bat_props[] = {
	POWER_SUPPLY_PROP_STATUS,
	POWER_SUPPLY_PROP_CHARGE_TYPE,
	POWER_SUPPLY_PROP_PRESENT,
@@ -348,6 +348,23 @@ static enum power_supply_property olpc_bat_props[] = {
	POWER_SUPPLY_PROP_CHARGE_COUNTER,
};

/* XO-1.5 does not have ambient temperature property */
static enum power_supply_property olpc_xo15_bat_props[] = {
	POWER_SUPPLY_PROP_STATUS,
	POWER_SUPPLY_PROP_CHARGE_TYPE,
	POWER_SUPPLY_PROP_PRESENT,
	POWER_SUPPLY_PROP_HEALTH,
	POWER_SUPPLY_PROP_TECHNOLOGY,
	POWER_SUPPLY_PROP_VOLTAGE_AVG,
	POWER_SUPPLY_PROP_CURRENT_AVG,
	POWER_SUPPLY_PROP_CAPACITY,
	POWER_SUPPLY_PROP_CAPACITY_LEVEL,
	POWER_SUPPLY_PROP_TEMP,
	POWER_SUPPLY_PROP_MANUFACTURER,
	POWER_SUPPLY_PROP_SERIAL_NUMBER,
	POWER_SUPPLY_PROP_CHARGE_COUNTER,
};

/* EEPROM reading goes completely around the power_supply API, sadly */

#define EEPROM_START	0x20
@@ -419,8 +436,6 @@ static struct device_attribute olpc_bat_error = {
static struct platform_device *bat_pdev;

static struct power_supply olpc_bat = {
	.properties = olpc_bat_props,
	.num_properties = ARRAY_SIZE(olpc_bat_props),
	.get_property = olpc_bat_get_property,
	.use_for_apm = 1,
};
@@ -466,6 +481,13 @@ static int __init olpc_bat_init(void)
		goto ac_failed;

	olpc_bat.name = bat_pdev->name;
	if (olpc_board_at_least(olpc_board_pre(0xd0))) { /* XO-1.5 */
		olpc_bat.properties = olpc_xo15_bat_props;
		olpc_bat.num_properties = ARRAY_SIZE(olpc_xo15_bat_props);
	} else { /* XO-1 */
		olpc_bat.properties = olpc_xo1_bat_props;
		olpc_bat.num_properties = ARRAY_SIZE(olpc_xo1_bat_props);
	}

	ret = power_supply_register(&bat_pdev->dev, &olpc_bat);
	if (ret)