Input: trackpoint - Optimize trackpoint init to use power-on reset
The trackpoint driver sets various parameter default values, all of which happen to be power-on defaults (Source: IBM TrackPoint Engineering Specification, Version 4.0. Also confirmed by empirical data). By sending the power-on reset command to reset all parameters to power-on state, we can skip the lengthy process of programming all parameters. In testing, ~2.5 secs of time writing parameters was reduced to .35 seconds waiting for power-on reset to complete. Signed-off-by:Shawn Nematbakhsh <shawnn@chromium.org> Signed-off-by:
Dmitry Torokhov <dmitry.torokhov@gmail.com>