Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Skip to content
Commit 08408d2e authored by Osvaldo Banuelos's avatar Osvaldo Banuelos
Browse files

ARM: dts: msm: config SDM845 CPRh controllers to use default step_quot



Configure VDD_APC0 and VDD_APC1 CPRh controllers to initially
use the default step_quot and then later switch to the run-time
calibrated step_quot. This may help in some cases where closed-loop
voltage gets stuck at the open-loop voltage following a DCVS switch.

Change-Id: Ia66308a92363b9f0c78610f6f4fd7c41827bdfc0
Signed-off-by: default avatarOsvaldo Banuelos <osvaldob@codeaurora.org>
parent 718bc804