Don't handle server respons after it was deallocated

After a request is send to the GATT server, it might timeout, or get
cancelled, i.e. by client unregistering. If a response to such request
is later received, it should not be parsed. Currently such response is
parsed, and can call the response callback again, also on already
unregistered app.

Test: compilation test
Change-Id: Ia76770a693cd35d49973462c4d233d70f8a4e165
parent b63e2798
Loading
Loading
Loading
Loading
+32 −40
Original line number Diff line number Diff line
@@ -1034,44 +1034,45 @@ bool gatt_cl_send_next_cmd_inq(tGATT_TCB& tcb) {
  return false;
}

/*******************************************************************************
 *
 * Function         gatt_client_handle_server_rsp
 *
 * Description      This function is called to handle the server response to
 *                  client.
 *
 *
 * Returns          void
 *
 ******************************************************************************/
/** This function is called to handle the server response to client */
void gatt_client_handle_server_rsp(tGATT_TCB& tcb, uint8_t op_code,
                                   uint16_t len, uint8_t* p_data) {
  tGATT_CLCB* p_clcb = NULL;

  if (op_code != GATT_HANDLE_VALUE_IND && op_code != GATT_HANDLE_VALUE_NOTIF) {
    uint8_t rsp_code;
    p_clcb = gatt_cmd_dequeue(tcb, &rsp_code);
  if (op_code == GATT_HANDLE_VALUE_IND || op_code == GATT_HANDLE_VALUE_NOTIF) {
    if (len >= tcb.payload_size) {
      GATT_TRACE_ERROR("%s: invalid indicate pkt size: %d, PDU size: %d",
                       __func__, len + 1, tcb.payload_size);
      return;
    }

    rsp_code = gatt_cmd_to_rsp_code(rsp_code);
    gatt_process_notification(tcb, op_code, len, p_data);
    return;
  }

    if (p_clcb == NULL || (rsp_code != op_code && op_code != GATT_RSP_ERROR)) {
  uint8_t cmd_code = 0;
  tGATT_CLCB* p_clcb = gatt_cmd_dequeue(tcb, &cmd_code);
  uint8_t rsp_code = gatt_cmd_to_rsp_code(cmd_code);
  if (!p_clcb || (rsp_code != op_code && op_code != GATT_RSP_ERROR)) {
    GATT_TRACE_WARNING(
        "ATT - Ignore wrong response. Receives (%02x) Request(%02x) Ignored",
        op_code, rsp_code);
    return;
  }

  if (!p_clcb->in_use) {
    GATT_TRACE_WARNING("ATT - clcb already not in use, ignoring response");
    gatt_cl_send_next_cmd_inq(tcb);
    return;
  }

  alarm_cancel(p_clcb->gatt_rsp_timer_ent);
  p_clcb->retry_count = 0;
  }

  /* the size of the message may not be bigger than the local max PDU size*/
  /* The message has to be smaller than the agreed MTU, len does not count
   * op_code */
  if (len >= tcb.payload_size) {
    GATT_TRACE_ERROR("invalid response/indicate pkt size: %d, PDU size: %d",
                     len + 1, tcb.payload_size);
    if (op_code != GATT_HANDLE_VALUE_NOTIF && op_code != GATT_HANDLE_VALUE_IND)
    GATT_TRACE_ERROR("%s: invalid response pkt size: %d, PDU size: %d",
                     __func__, len + 1, tcb.payload_size);
    gatt_end_operation(p_clcb, GATT_ERROR, NULL);
  } else {
    switch (op_code) {
@@ -1114,20 +1115,11 @@ void gatt_client_handle_server_rsp(tGATT_TCB& tcb, uint8_t op_code,
        gatt_end_operation(p_clcb, p_clcb->status, NULL);
        break;

      case GATT_HANDLE_VALUE_NOTIF:
      case GATT_HANDLE_VALUE_IND:
        gatt_process_notification(tcb, op_code, len, p_data);
        break;

      default:
        GATT_TRACE_ERROR("Unknown opcode = %d", op_code);
        GATT_TRACE_ERROR("%s: Unknown opcode = %d", __func__, op_code);
        break;
    }
  }

  if (op_code != GATT_HANDLE_VALUE_IND && op_code != GATT_HANDLE_VALUE_NOTIF) {
  gatt_cl_send_next_cmd_inq(tcb);
}

  return;
}