Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Commit 4b938358 authored by Pengquan Meng's avatar Pengquan Meng
Browse files

Fixed Invalid Pdu Issue

The device may receive invalid sms pdu, i.e the pdu contins sms header
with an invalid seqNumber. This caused InboundSmsHandler crashed constantly.
This CL added the range check for the seqNumber to ensure the
InboundSmsHandler will not crash even if the seqNumber is invalid.

Bug: 72298611
Test: no test

Merged-In: I219961d63bbb3b9195cfea8b38a877a00af70522
Merged-In: Icf291c8530abdc2a528c5cf227cf00135281b899
Change-Id: I5e9ac1248bb87991547639b594b32a769c86eab3
parent 3e976736
Loading
Loading
Loading
Loading
+29 −0
Original line number Diff line number Diff line
@@ -66,6 +66,7 @@ import android.telephony.SmsMessage;
import android.telephony.SubscriptionManager;
import android.telephony.TelephonyManager;
import android.text.TextUtils;
import android.util.EventLog;

import com.android.internal.telephony.uicc.UiccCard;
import com.android.internal.telephony.uicc.UiccController;
@@ -691,6 +692,18 @@ public abstract class InboundSmsHandler extends StateMachine {
        byte[][] pdus;
        int destPort = tracker.getDestPort();

        // Do not process when the message count is invalid.
        if (messageCount <= 0) {
            EventLog.writeEvent(
                    0x534e4554 /* snetTagId */,
                    "72298611" /* buganizer id */,
                    -1 /* uid */,
                    String.format(
                        "processMessagePart: invalid messageCount = %d",
                        messageCount));
            return false;
        }

        if (messageCount == 1) {
            // single-part message
            pdus = new byte[][]{tracker.getPdu()};
@@ -724,6 +737,22 @@ public abstract class InboundSmsHandler extends StateMachine {
                    // subtract offset to convert sequence to 0-based array index
                    int index = cursor.getInt(SEQUENCE_COLUMN) - tracker.getIndexOffset();

                    // The invalid PDUs can be received and stored in the raw table. The range
                    // check ensures the process not crash even if the seqNumber in the
                    // UserDataHeader is invalid.
                    if (index >= pdus.length || index < 0) {
                        EventLog.writeEvent(
                                0x534e4554 /* snetTagId */,
                                "72298611" /* buganizer id */,
                                -1 /* uid */,
                                String.format(
                                    "processMessagePart: invalid seqNumber = %d, "
                                    + "messageCount = %d",
                                    index + tracker.getIndexOffset(),
                                    messageCount));
                        continue;
                    }

                    pdus[index] = HexDump.hexStringToByteArray(cursor.getString(PDU_COLUMN));

                    // Read the destination port from the first segment (needed for CDMA WAP PDU).