Commit 3f6755f5 authored by Jinsuk Kim's avatar Jinsuk Kim
Browse files

CEC: Check command type for power status monitor action

The action was not checking the command type before processing.
Makes sure the right command is given for the rest of the action flow.

Bug: 18592547
Change-Id: Iaf2584501fc70bfc87e00b74f48cb11c6989f283
parent dad92f36
Loading
Loading
Loading
Loading
+4 −3
Original line number Diff line number Diff line
@@ -64,11 +64,12 @@ public class PowerStatusMonitorAction extends HdmiCecFeatureAction {

    @Override
    boolean processCommand(HdmiCecMessage cmd) {
        if (mState != STATE_WAIT_FOR_REPORT_POWER_STATUS) {
            return false;
        }
        if (mState == STATE_WAIT_FOR_REPORT_POWER_STATUS
                && cmd.getOpcode() == Constants.MESSAGE_REPORT_POWER_STATUS) {
            return handleReportPowerStatus(cmd);
        }
        return false;
    }

    private boolean handleReportPowerStatus(HdmiCecMessage cmd) {
        int sourceAddress = cmd.getSource();