Commit 80195724 authored by Kelvin Zhang's avatar Kelvin Zhang
Browse files

Allow downgradable partial OTA

Cuttlefish doesn't support updatin vendor partition. So in testing we
need to exclude vendor and generate a downgrade partial package.

Test: generate a partial downgrade OTA
Bug: 171999375
Change-Id: I97e450d4063320cf55003a7a5c5ef913c321e067
parent a0aebc10
Loading
Loading
Loading
Loading
+31 −9
Original line number Diff line number Diff line
@@ -955,6 +955,19 @@ def GeneratePartitionTimestampFlags(partition_state):
      for part in partition_state]
  return ["--partition_timestamps", ",".join(partition_timestamps)]

def GeneratePartitionTimestampFlagsDowngrade(pre_partition_state, post_partition_state):
  assert pre_partition_state is not None
  partition_timestamps = {}
  for part in pre_partition_state:
    partition_timestamps[part.partition_name] = part.version
  for part in post_partition_state:
    partition_timestamps[part.partition_name] = \
      max(part.version, partition_timestamps[part.partition_name])
  return [
    "--partition_timestamps",
    ",".join([key + ":" + val for (key, val) in partition_timestamps.items()])
    ]

def GenerateAbOtaPackage(target_file, output_file, source_file=None):
  """Generates an Android OTA package that has A/B update payload."""
  # Stage the output zip package for package signing.
@@ -1015,6 +1028,10 @@ def GenerateAbOtaPackage(target_file, output_file, source_file=None):
  # Enforce a max timestamp this payload can be applied on top of.
  if OPTIONS.downgrade:
    max_timestamp = source_info.GetBuildProp("ro.build.date.utc")
    partition_timestamps_flags = GeneratePartitionTimestampFlagsDowngrade(
      metadata.precondition.partition_state,
      metadata.postcondition.partition_state
      )
  else:
    max_timestamp = str(metadata.postcondition.timestamp)
    partition_timestamps_flags = GeneratePartitionTimestampFlags(
@@ -1226,15 +1243,6 @@ def main(argv):

  common.InitLogging()

  if OPTIONS.downgrade:
    # We should only allow downgrading incrementals (as opposed to full).
    # Otherwise the device may go back from arbitrary build with this full
    # OTA package.
    if OPTIONS.incremental_source is None:
      raise ValueError("Cannot generate downgradable full OTAs")
    if OPTIONS.partial:
      raise ValueError("Cannot generate downgradable partial OTAs")

  # Load the build info dicts from the zip directly or the extracted input
  # directory. We don't need to unzip the entire target-files zips, because they
  # won't be needed for A/B OTAs (brillo_update_payload does that on its own).
@@ -1246,6 +1254,19 @@ def main(argv):
    OPTIONS.info_dict = common.LoadInfoDict(OPTIONS.extracted_input)
  else:
    OPTIONS.info_dict = ParseInfoDict(args[0])
  if OPTIONS.partial:
    OPTIONS.info_dict['ab_partitions'] = \
      list(
        set(OPTIONS.info_dict['ab_partitions']) & set(OPTIONS.partial)
        )

  if OPTIONS.downgrade:
    # We should only allow downgrading incrementals (as opposed to full).
    # Otherwise the device may go back from arbitrary build with this full
    # OTA package.
    if OPTIONS.incremental_source is None:
      raise ValueError("Cannot generate downgradable full OTAs")


  # TODO(xunchang) for retrofit and partial updates, maybe we should rebuild the
  # target-file and reload the info_dict. So the info will be consistent with
@@ -1254,6 +1275,7 @@ def main(argv):
  logger.info("--- target info ---")
  common.DumpInfoDict(OPTIONS.info_dict)


  # Load the source build dict if applicable.
  if OPTIONS.incremental_source is not None:
    OPTIONS.target_info_dict = OPTIONS.info_dict