Fix the fuse error that cannot handle the OTA package larger than 4 GiB



1. That read data will be blocked when adb sideload OTA package
2. An error(Out of bound read) occurs when installing OTA package by fuse

Test: as follows
    - adb sideload OTA package
    - install OTA package by install_with_fuse parameter

Change-Id: Ie53510d157f6ea4c92606b289fcb745d441918c8
Signed-off-by: default avatarluoqiangwei1 <luoqiangwei1@xiaomi.com>
parent 436a520a
Loading
Loading
Loading
Loading
+1 −1
Original line number Diff line number Diff line
@@ -225,7 +225,7 @@ static int handle_release(void* /* data */, fuse_data* /* fd */, const fuse_in_h

// Fetch a block from the host into fd->curr_block and fd->block_data.
// Returns 0 on successful fetch, negative otherwise.
static int fetch_block(fuse_data* fd, uint32_t block) {
static int fetch_block(fuse_data* fd, uint64_t block) {
  if (block == fd->curr_block) {
    return 0;
  }