Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Commit ff871848 authored by Tirupathi Reddy's avatar Tirupathi Reddy
Browse files

ARM: dts: msm: Update APC CPR static voltage margins for msm8953



Update APC CPR closed-loop voltage margins based on latest
recommendation.

CRs-Fixed: 1005902
Change-Id: I67d0695a83cabc66c3587397a8b1df2c7197470a
Signed-off-by: default avatarTirupathi Reddy <tirupath@codeaurora.org>
parent a3df2e4c
Loading
Loading
Loading
Loading
+9 −9
Original line number Diff line number Diff line
@@ -636,9 +636,9 @@
				qcom,cpr-closed-loop-voltage-fuse-adjustment =
					/* Speed bin 0; CPR rev 0..7 */
					<      0        0        0      0>,
					<  25000        0    20000  50000>,
					<  25000        0    20000  50000>,
					<  25000        0    20000  50000>,
					<  10000 (-15000)        0  25000>,
					<  10000 (-15000)        0  25000>,
					<  10000 (-15000)        0  25000>,
					<      0        0        0      0>,
					<      0        0        0      0>,
					<      0        0        0      0>,
@@ -656,9 +656,9 @@

					/* Speed bin 2; CPR rev 0..7 */
					<      0        0        0      0>,
					<  25000        0    20000  50000>,
					<  25000        0    20000  50000>,
					<  25000        0    20000  50000>,
					<  10000 (-15000)        0  25000>,
					<  10000 (-15000)        0  25000>,
					<  10000 (-15000)        0  25000>,
					<      0        0        0      0>,
					<      0        0        0      0>,
					<      0        0        0      0>,
@@ -706,9 +706,9 @@

					/* Speed bin 7; CPR rev 0..7 */
					<      0        0        0      0>,
					<  25000        0    20000  50000>,
					<  25000        0    20000  50000>,
					<  25000        0    20000  50000>,
					<  10000 (-15000)        0  25000>,
					<  10000 (-15000)        0  25000>,
					<  10000 (-15000)        0  25000>,
					<      0        0        0      0>,
					<      0        0        0      0>,
					<      0        0        0      0>,