Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Commit f2a371c5 authored by NeilBrown's avatar NeilBrown
Browse files

md: notify the 'degraded' sysfs attribute on failure.



We currently only 'notify' changes to the 'degraded' attribute
when it decreases, not when it increases.

Notifying on failure is a little awkward as it happen in
interrupt context.
So instead, notify when we remove the failed device from the array,
which is very soon afterwards.

Reported-and-tested-by: default avatarMikhail Balabin <mbalabin@gmail.com>
Signed-off-by: default avatarNeilBrown <neilb@suse.de>
parent 19d67169
Loading
Loading
Loading
Loading
+6 −0
Original line number Diff line number Diff line
@@ -7383,6 +7383,7 @@ static int remove_and_add_spares(struct mddev *mddev)
{
	struct md_rdev *rdev;
	int spares = 0;
	int removed = 0;

	mddev->curr_resync_completed = 0;

@@ -7396,8 +7397,13 @@ static int remove_and_add_spares(struct mddev *mddev)
				    mddev, rdev) == 0) {
				sysfs_unlink_rdev(mddev, rdev);
				rdev->raid_disk = -1;
				removed++;
			}
		}
	if (removed)
		sysfs_notify(&mddev->kobj, NULL,
			     "degraded");


	list_for_each_entry(rdev, &mddev->disks, same_set) {
		if (rdev->raid_disk >= 0 &&