Commit e6e03dae authored by Michael Karcher's avatar Michael Karcher Committed by Takashi Iwai
Browse files

ALSA: hda - Remove CD control from model=benq for CX20549



The ID used for detection of the BenQ R55E actually identifies the
Quanta TW3 ODM design, which is also used for the Gigabyte W551 laptop
series. Schematics on the internet clearly indicate that the "Port C"
(analog input connected to record source #4 and mixer input #4) is
unconnected.

Playing an audio CD through analog playback (using cdplay from cdtools)
produces no sound, even with the mixer input labelled "CD" enabled, and
the volume control in the CD drive set to maximum. This indicates the
connection is really not present.

Signed-off-by: default avatarMichael Karcher <kernel@mkarcher.dialup.fu-berlin.de>
Signed-off-by: default avatarTakashi Iwai <tiwai@suse.de>
parent cbf2d28e
Loading
Loading
Loading
Loading
+1 −5
Original line number Diff line number Diff line
@@ -692,9 +692,8 @@ static const struct hda_input_mux cxt5045_capture_source = {
};

static const struct hda_input_mux cxt5045_capture_source_benq = {
	.num_items = 5,
	.num_items = 4,
	.items = {
		{ "CD",           0x4 },
		{ "Internal Mic", 0x1 },
		{ "Mic",          0x2 },
		{ "Line",         0x3 },
@@ -819,9 +818,6 @@ static const struct snd_kcontrol_new cxt5045_mixers[] = {
};

static const struct snd_kcontrol_new cxt5045_benq_mixers[] = {
	HDA_CODEC_VOLUME("CD Playback Volume", 0x17, 0x4, HDA_INPUT),
	HDA_CODEC_MUTE("CD Playback Switch", 0x17, 0x4, HDA_INPUT),

	HDA_CODEC_VOLUME("Line Playback Volume", 0x17, 0x3, HDA_INPUT),
	HDA_CODEC_MUTE("Line Playback Switch", 0x17, 0x3, HDA_INPUT),