Thermal/int3403: Fix thermal hysteresis unit conversion



Thermal hysteresis represents a temperature difference.
But the original code treats it as a temperature value,
Convert it from tenths of degree Kelvin to Milli-Celsius
by deducing 273200. This is not right.

Kelvin and Celsius have same degree size. From temperature
difference view, the conversion between tenths of degree
Kelvin unit and Milli-Celsius unit is just to multiply 100.

Signed-off-by: default avatarLan Tianyu <tianyu.lan@intel.com>
Acked-by: default avatarSrinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: default avatarZhang Rui <rui.zhang@intel.com>
parent d6d211db
Loading
Loading
Loading
Loading
+7 −1
Original line number Diff line number Diff line
@@ -62,7 +62,13 @@ static int sys_get_trip_hyst(struct thermal_zone_device *tzone,
	if (ACPI_FAILURE(status))
		return -EIO;

	*temp = DECI_KELVIN_TO_MILLI_CELSIUS(hyst, KELVIN_OFFSET);
	/*
	 * Thermal hysteresis represents a temperature difference.
	 * Kelvin and Celsius have same degree size. So the
	 * conversion here between tenths of degree Kelvin unit
	 * and Milli-Celsius unit is just to multiply 100.
	 */
	*temp = hyst * 100;

	return 0;
}