ARM: dts: msm: Update APC CPR voltage margins for msm8920



Update APC CPR static open-loop and closed-loop voltage margins
for msm8920 as per new voltage characterization results.

CRs-Fixed: 1115776
Change-Id: Ief25d4eab816faccdd9e2d97ee1a5477867415cf
Signed-off-by: default avatarTirupathi Reddy <tirupath@codeaurora.org>
parent a1c3a94c
Loading
Loading
Loading
Loading
+3 −0
Original line number Diff line number Diff line
@@ -236,6 +236,7 @@
		<  0      0    (-1)   (-1)    (-1)    (-1)>,
		<  0      1      1    (-1)    (-1)    (-1)>,
		<  0      1    (-1)   (-1)    (-1)    (-1)>,
		<  0      5    (-1)   (-1)    (-1)    (-1)>,
		<(-1)   (-1)   (-1)   (-1)    (-1)    (-1)>;

	qcom,cpr-init-voltage-adjustment =
@@ -243,6 +244,7 @@
		<15000  15000   25000>,
		<  0     0        0  >,
		<15000   5000     0  >,
		< 5000  10000    5000>,
		<  0     0        0  >;

	qcom,cpr-quotient-adjustment =
@@ -250,6 +252,7 @@
		<0      0      19 >, /* SVSP(-5) NOM(-10) TUR(-5); KV(1.9) */
		<(-38) (-28) (-38)>, /* SVSP(-20) NOM(-15) TUR(-20); KV(1.9) */
		<0      0       0 >,
		<(-28)  0      10 >, /* SVSP(-15) TUR(5); KV(1.9) */
		<0      0       0 >;

	qcom,cpr-enable;