@@ -66,8 +66,8 @@ Sub IBB node required structure:
- qcom,qpnp-lab-init-lcd-voltage: The default voltage when IBB regulator working in lcd mode and the output voltage register of value 0
- qcom,qpnp-ibb-discharge-resistor: The discharge resistor in Kilo Ohm who controls the soft start time. Supported values are 300, 64, 32 and 16.
- qcom,qpnp-ibb-lab-pwrup-delay: The delay in us of IBB regulator during power up. Supported value are 1250, 2500, 5000 and 10000.
- qcom,qpnp-ibb-lab-pwrdn-delay: The delay in us of IBB regulator during power down. Supported value are 1250, 2500, 5000 and 10000.
- qcom,qpnp-ibb-lab-pwrup-delay: Power up delay (in us) for IBB regulator when it is enabled or turned on. Supported value are 1000, 2000, 4000 and 8000.
- qcom,qpnp-ibb-lab-pwrdn-delay: Power down delay (in us) for IBB regulator when it is disabled or turned off. Supported value are 1000, 2000, 4000 and 8000.
- qcom,qpnp-ibb-switching-clock-frequency: The PWM switching clock frequency in kHz of IBB regulator, supported value are