Loading arch/arm/boot/dts/qcom/msm8996-regulator.dtsi +10 −0 Original line number Diff line number Diff line Loading @@ -1260,6 +1260,16 @@ <0 70000 70000 75000 80000 90000 95000 100000>; qcom,cpr-fused-closed-loop-voltage-adjustment-map = <0 0 0 0 0 0 0 0>, <0 0 0 0 0 0 0 0>, <0 0 0 0 0 0 0 0>, <0 0 0 0 0 0 0 0>, <0 2 2 2 2 0 0 4>, <0 2 2 2 2 0 0 4>, <0 2 2 2 2 0 0 4>, <0 2 2 2 2 0 0 4>; qcom,allow-voltage-interpolation; qcom,cpr-scaled-open-loop-voltage-as-ceiling; Loading arch/arm/boot/dts/qcom/msm8996-v2.dtsi +2 −0 Original line number Diff line number Diff line Loading @@ -342,6 +342,8 @@ qcom,cpr-floor-to-ceiling-max-range = <0 130000 40000 85000 85000>; /delete-property/ qcom,cpr-fused-closed-loop-voltage-adjustment-map; /delete-property/ qcom,cpr-aging-max-voltage-adjustment; /delete-property/ qcom,cpr-aging-ref-corner; /delete-property/ qcom,cpr-aging-ro-scaling-factor; Loading arch/arm/boot/dts/qcom/msm8996-v3.0.dtsi +2 −0 Original line number Diff line number Diff line Loading @@ -104,6 +104,8 @@ qcom,cpr-floor-to-ceiling-max-range = <0 70000 75000 80000 90000 95000 100000>; /delete-property/ qcom,cpr-fused-closed-loop-voltage-adjustment-map; qcom,allow-voltage-interpolation; qcom,cpr-scaled-open-loop-voltage-as-ceiling; Loading Loading
arch/arm/boot/dts/qcom/msm8996-regulator.dtsi +10 −0 Original line number Diff line number Diff line Loading @@ -1260,6 +1260,16 @@ <0 70000 70000 75000 80000 90000 95000 100000>; qcom,cpr-fused-closed-loop-voltage-adjustment-map = <0 0 0 0 0 0 0 0>, <0 0 0 0 0 0 0 0>, <0 0 0 0 0 0 0 0>, <0 0 0 0 0 0 0 0>, <0 2 2 2 2 0 0 4>, <0 2 2 2 2 0 0 4>, <0 2 2 2 2 0 0 4>, <0 2 2 2 2 0 0 4>; qcom,allow-voltage-interpolation; qcom,cpr-scaled-open-loop-voltage-as-ceiling; Loading
arch/arm/boot/dts/qcom/msm8996-v2.dtsi +2 −0 Original line number Diff line number Diff line Loading @@ -342,6 +342,8 @@ qcom,cpr-floor-to-ceiling-max-range = <0 130000 40000 85000 85000>; /delete-property/ qcom,cpr-fused-closed-loop-voltage-adjustment-map; /delete-property/ qcom,cpr-aging-max-voltage-adjustment; /delete-property/ qcom,cpr-aging-ref-corner; /delete-property/ qcom,cpr-aging-ro-scaling-factor; Loading
arch/arm/boot/dts/qcom/msm8996-v3.0.dtsi +2 −0 Original line number Diff line number Diff line Loading @@ -104,6 +104,8 @@ qcom,cpr-floor-to-ceiling-max-range = <0 70000 75000 80000 90000 95000 100000>; /delete-property/ qcom,cpr-fused-closed-loop-voltage-adjustment-map; qcom,allow-voltage-interpolation; qcom,cpr-scaled-open-loop-voltage-as-ceiling; Loading