Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Commit 5957e444 authored by Laxman Dewangan's avatar Laxman Dewangan Committed by Mark Brown
Browse files

regulator: palmas: configure enable time for LDOs



As per datasheet (Referred TPS65913), the on-time for LDO is
500micro second. If LDO6 is in vibrator mode then the on-time
is 2000us.

Set the enable_time on regulator descriptor accordingly.

Signed-off-by: default avatarLaxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: default avatarMark Brown <broonie@linaro.org>
parent 32b6d3f6
Loading
Loading
Loading
Loading
+6 −0
Original line number Diff line number Diff line
@@ -1127,6 +1127,7 @@ static int palmas_regulators_probe(struct platform_device *pdev)
			pmic->desc[id].min_uV = 900000;
			pmic->desc[id].uV_step = 50000;
			pmic->desc[id].linear_min_sel = 1;
			pmic->desc[id].enable_time = 500;
			pmic->desc[id].vsel_reg =
					PALMAS_BASE_TO_REG(PALMAS_LDO_BASE,
						palmas_regs_info[id].vsel_addr);
@@ -1145,6 +1146,11 @@ static int palmas_regulators_probe(struct platform_device *pdev)
				pmic->desc[id].min_uV = 450000;
				pmic->desc[id].uV_step = 25000;
			}

			/* LOD6 in vibrator mode will have enable time 2000us */
			if (pdata && pdata->ldo6_vibrator &&
				(id == PALMAS_REG_LDO6))
				pmic->desc[id].enable_time = 2000;
		} else {
			pmic->desc[id].n_voltages = 1;
			if (reg_init && reg_init->roof_floor)