net/mlx4_en: Run loopback test only when port is up



Loopback can't work when port is down.

Signed-off-by: default avatarEugenia Emantayev <eugenia@mellanox.com>

Signed-off-by: default avatarAmir Vadai <amirv@mellanox.com>
Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>
parent 523ece88
Loading
Loading
Loading
Loading
+2 −1
Original line number Diff line number Diff line
@@ -159,6 +159,7 @@ void mlx4_en_ex_selftest(struct net_device *dev, u32 *flags, u64 *buf)
		if (priv->mdev->dev->caps.flags &
					MLX4_DEV_CAP_FLAG_UC_LOOPBACK) {
			buf[3] = mlx4_en_test_registers(priv);
			if (priv->port_up)
				buf[4] = mlx4_en_test_loopback(priv);
		}