Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Commit 3f158c25 authored by Wolfram Sang's avatar Wolfram Sang Committed by David S. Miller
Browse files

net/can/mpc52xx_can: refactor clock-get routine



Merge two functions into one. The result is smaller as they can now share some
variables.

Signed-off-by: default avatarWolfram Sang <w.sang@pengutronix.de>
Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>
parent 68bd7422
Loading
Loading
Loading
Loading
+16 −29
Original line number Diff line number Diff line
@@ -38,28 +38,37 @@

static struct of_device_id mpc52xx_cdm_ids[] __devinitdata = {
	{ .compatible = "fsl,mpc5200-cdm", },
	{ .compatible = "fsl,mpc5200b-cdm", },
	{}
};

/*
 * Get the frequency of the external oscillator clock connected
 * to the SYS_XTAL_IN pin, or return 0 if it cannot be determined.
 * Get frequency of the MSCAN clock source
 *
 * Either the oscillator clock (SYS_XTAL_IN) or the IP bus clock (IP_CLK)
 * can be selected. According to the MPC5200 user's manual, the oscillator
 * clock is the better choice as it has less jitter but due to a hardware
 * bug, it can not be selected for the old MPC5200 Rev. A chips.
 */
static unsigned int  __devinit mpc52xx_can_xtal_freq(struct of_device *of)

static unsigned int  __devinit mpc52xx_can_clock_freq(struct of_device *of,
						      int clock_src)
{
	unsigned int pvr;
	struct mpc52xx_cdm  __iomem *cdm;
	struct device_node *np_cdm;
	unsigned int freq;
	u32 val;

	pvr = mfspr(SPRN_PVR);

	freq = mpc5xxx_get_bus_frequency(of->node);
	if (!freq)
		return 0;

	/*
	 * Determine SYS_XTAL_IN frequency from the clock domain settings
	 */
	if (clock_src == MSCAN_CLKSRC_BUS || pvr == 0x80822011)
		return freq;

	/* Determine SYS_XTAL_IN frequency from the clock domain settings */
	np_cdm = of_find_matching_node(NULL, mpc52xx_cdm_ids);
	if (!np_cdm) {
		dev_err(&of->dev, "can't get clock node!\n");
@@ -80,28 +89,6 @@ static unsigned int __devinit mpc52xx_can_xtal_freq(struct of_device *of)
	return freq;
}

/*
 * Get frequency of the MSCAN clock source
 *
 * Either the oscillator clock (SYS_XTAL_IN) or the IP bus clock (IP_CLK)
 * can be selected. According to the MPC5200 user's manual, the oscillator
 * clock is the better choice as it has less jitter but due to a hardware
 * bug, it can not be selected for the old MPC5200 Rev. A chips.
 */

static unsigned int  __devinit mpc52xx_can_clock_freq(struct of_device *of,
						      int clock_src)
{
	unsigned int pvr;

	pvr = mfspr(SPRN_PVR);

	if (clock_src == MSCAN_CLKSRC_BUS || pvr == 0x80822011)
		return mpc5xxx_get_bus_frequency(of->node);

	return mpc52xx_can_xtal_freq(of);
}

static int __devinit mpc5xxx_can_probe(struct of_device *ofdev,