mwifiex: shorten per channel scan time



Currently the scan time per channel for active scanning is set to
200ms. It takes quite a while to finsh scanning on all channels,
especially with a dual band configuration.

Change the per channel scan time settings to the following values:

passive scan: 110ms
active scan: 30ms
specific scan: 30ms

Above settings have been tested on x86 and arm platforms.

Signed-off-by: default avatarBing Zhao <bzhao@marvell.com>
Signed-off-by: default avatarAmitkumar Karwar <akarwar@marvell.com>
Signed-off-by: default avatarJohn W. Linville <linville@tuxdriver.com>
parent b6038961
Loading
Loading
Loading
Loading
+3 −3
Original line number Diff line number Diff line
@@ -79,9 +79,9 @@ enum {

#define SCAN_BEACON_ENTRY_PAD			6

#define MWIFIEX_PASSIVE_SCAN_CHAN_TIME	200
#define MWIFIEX_ACTIVE_SCAN_CHAN_TIME	200
#define MWIFIEX_SPECIFIC_SCAN_CHAN_TIME	110
#define MWIFIEX_PASSIVE_SCAN_CHAN_TIME	110
#define MWIFIEX_ACTIVE_SCAN_CHAN_TIME	30
#define MWIFIEX_SPECIFIC_SCAN_CHAN_TIME	30

#define SCAN_RSSI(RSSI)					(0x100 - ((u8)(RSSI)))