Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Commit 1c9573a4 authored by Eduardo Valentin's avatar Eduardo Valentin Committed by Zhang Rui
Browse files

thermal: fix cpu_cooling max_level behavior



As per Documentation/thermal/sysfs-api.txt, max_level
is an index, not a counter. Thus, in case a CPU has
3 valid frequencies, max_level is expected to be 2, for instance.

The current code makes max_level == number of valid frequencies,
which is bogus. This patch fix the cpu_cooling device by
ranging max_level properly.

Reported-by: default avatarCarlos Hernandez <ceh@ti.com>
Signed-off-by: default avatarEduardo Valentin <eduardo.valentin@ti.com>
Signed-off-by: default avatarZhang Rui <rui.zhang@intel.com>
parent 06475b55
Loading
Loading
Loading
Loading
+4 −2
Original line number Diff line number Diff line
@@ -173,6 +173,8 @@ static int get_property(unsigned int cpu, unsigned long input,
		freq = table[i].frequency;
		max_level++;
	}
	/* max_level is an index, not a counter */
	max_level--;

	/* get max level */
	if (property == GET_MAXL) {
@@ -181,7 +183,7 @@ static int get_property(unsigned int cpu, unsigned long input,
	}

	if (property == GET_FREQ)
		level = descend ? input : (max_level - input - 1);
		level = descend ? input : (max_level - input);

	for (i = 0, j = 0; table[i].frequency != CPUFREQ_TABLE_END; i++) {
		/* ignore invalid entry */
@@ -197,7 +199,7 @@ static int get_property(unsigned int cpu, unsigned long input,

		if (property == GET_LEVEL && (unsigned int)input == freq) {
			/* get level by frequency */
			*output = descend ? j : (max_level - j - 1);
			*output = descend ? j : (max_level - j);
			return 0;
		}
		if (property == GET_FREQ && level == j) {