Commit 0873a5ae authored by Erik J. Staab's avatar Erik J. Staab Committed by Takashi Iwai
Browse files

ALSA: oxygen: fix analog capture on Claro halo cards



On the HT-Omega Claro halo card, the ADC data must be captured from the
second I2S input.  Using the default first input, which isn't connected
to anything, would result in silence.

Signed-off-by: default avatarErik J. Staab <ejs@insightbb.com>
Signed-off-by: default avatarClemens Ladisch <clemens@ladisch.de>
Cc: <stable@kernel.org>
Signed-off-by: default avatarTakashi Iwai <tiwai@suse.de>
parent b30a3f62
Loading
Loading
Loading
Loading
+4 −0
Original line number Diff line number Diff line
@@ -543,6 +543,10 @@ static int __devinit get_oxygen_model(struct oxygen *chip,
		chip->model.suspend = claro_suspend;
		chip->model.resume = claro_resume;
		chip->model.set_adc_params = set_ak5385_params;
		chip->model.device_config = PLAYBACK_0_TO_I2S |
					    PLAYBACK_1_TO_SPDIF |
					    CAPTURE_0_FROM_I2S_2 |
					    CAPTURE_1_FROM_SPDIF;
		break;
	}
	if (id->driver_data == MODEL_MERIDIAN ||