dt-bindings: mvebu-uart: update documentation with extended UART



Update the device tree binding documentation for the Marvell EBU UART,
in order to allow describing the extended UART IP block, in addition to
the already supported standard UART IP. This requires adding a new
compatible string, the introduction of a clocks property, and extensions
to the interrupts property.

Signed-off-by: default avatarMiquel Raynal <miquel.raynal@free-electrons.com>
Reviewed-by: default avatarGregory CLEMENT <gregory.clement@free-electrons.com>
Acked-by: default avatarRob Herring <robh@kernel.org>
Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@linuxfoundation.org>
parent 5c305539
Loading
Loading
Loading
Loading
+45 −5
Original line number Diff line number Diff line
* Marvell UART : Non standard UART used in some of Marvell EBU SoCs (e.g., Armada-3700)
* Marvell UART : Non standard UART used in some of Marvell EBU SoCs
                 e.g., Armada-3700.

Required properties:
- compatible: "marvell,armada-3700-uart"
- compatible:
    - "marvell,armada-3700-uart" for the standard variant of the UART
      (32 bytes FIFO, no DMA, level interrupts, 8-bit access to the
      FIFO, baudrate limited to 230400).
    - "marvell,armada-3700-uart-ext" for the extended variant of the
      UART (128 bytes FIFO, DMA, front interrupts, 8-bit or 32-bit
      accesses to the FIFO, baudrate unlimited by the dividers).
- reg: offset and length of the register set for the device.
- interrupts: device interrupt
- clocks: UART reference clock used to derive the baudrate. If no clock
      is provided (possible only with the "marvell,armada-3700-uart"
      compatible string for backward compatibility), it will only work
      if the baudrate was initialized by the bootloader and no baudrate
      change will then be possible.
- interrupts:
    - Must contain three elements for the standard variant of the IP
      (marvell,armada-3700-uart): "uart-sum", "uart-tx" and "uart-rx",
      respectively the UART sum interrupt, the UART TX interrupt and
      UART RX interrupt. A corresponding interrupt-names property must
      be defined.
    - Must contain two elements for the extended variant of the IP
      (marvell,armada-3700-uart-ext): "uart-tx" and "uart-rx",
      respectively the UART TX interrupt and the UART RX interrupt. A
      corresponding interrupts-names property must be defined.
    - For backward compatibility reasons, a single element interrupts
      property is also supported for the standard variant of the IP,
      containing only the UART sum interrupt. This form is deprecated
      and should no longer be used.

Example:
	serial@12000 {
	uart0: serial@12000 {
		compatible = "marvell,armada-3700-uart";
		reg = <0x12000 0x200>;
		interrupts = <43>;
		clocks = <&xtalclk>;
		interrupts =
		<GIC_SPI 11 IRQ_TYPE_LEVEL_HIGH>,
		<GIC_SPI 12 IRQ_TYPE_LEVEL_HIGH>,
		<GIC_SPI 13 IRQ_TYPE_LEVEL_HIGH>;
		interrupt-names = "uart-sum", "uart-tx", "uart-rx";
	};

	uart1: serial@12200 {
		compatible = "marvell,armada-3700-uart-ext";
		reg = <0x12200 0x30>;
		clocks = <&xtalclk>;
		interrupts =
		<GIC_SPI 30 IRQ_TYPE_EDGE_RISING>,
		<GIC_SPI 31 IRQ_TYPE_EDGE_RISING>;
		interrupt-names = "uart-tx", "uart-rx";
	};