staging: comedi: das800: remove 'forever' from private data



This member of the private data can be determined from the
cmd->stop_src. Do that instead.

Signed-off-by: default avatarH Hartley Sweeten <hsweeten@visionengravers.com>
Reviewed-by: default avatarIan Abbott <abbotti@mev.co.uk>
Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@linuxfoundation.org>
parent 8ffffae6
Loading
Loading
Loading
Loading
+9 −10
Original line number Diff line number Diff line
@@ -224,7 +224,6 @@ struct das800_private {
	unsigned int divisor1;	/* counter 1 value for timed conversions */
	unsigned int divisor2;	/* counter 2 value for timed conversions */
	unsigned int do_bits;	/* digital output bits */
	bool forever;		/* flag that we should take data forever */
};

static void das800_ind_write(struct comedi_device *dev,
@@ -290,7 +289,6 @@ static int das800_cancel(struct comedi_device *dev, struct comedi_subdevice *s)
{
	struct das800_private *devpriv = dev->private;

	devpriv->forever = false;
	devpriv->count = 0;
	das800_disable(dev);
	return 0;
@@ -425,13 +423,10 @@ static int das800_ai_do_cmd(struct comedi_device *dev,
	gain &= 0xf;
	outb(gain, dev->iobase + DAS800_GAIN);

	if (cmd->stop_src == TRIG_COUNT) {
	if (cmd->stop_src == TRIG_COUNT)
		devpriv->count = cmd->stop_arg * cmd->chanlist_len;
		devpriv->forever = false;
	} else {	/* TRIG_NONE */
		devpriv->forever = true;
	else	/* TRIG_NONE */
		devpriv->count = 0;
	}

	/* enable auto channel scan, send interrupts on end of conversion
	 * and set clock source to internal or external
@@ -467,7 +462,8 @@ static irqreturn_t das800_interrupt(int irq, void *d)
	struct comedi_device *dev = d;
	struct das800_private *devpriv = dev->private;
	struct comedi_subdevice *s = dev->read_subdev;
	struct comedi_async *async = s ? s->async : NULL;
	struct comedi_async *async;
	struct comedi_cmd *cmd;
	unsigned long irq_flags;
	unsigned int status;
	unsigned int val;
@@ -481,6 +477,9 @@ static irqreturn_t das800_interrupt(int irq, void *d)
	if (!dev->attached)
		return IRQ_HANDLED;

	async = s->async;
	cmd = &async->cmd;

	spin_lock_irqsave(&dev->spinlock, irq_flags);
	status = das800_ind_read(dev, CONTROL1) & STATUS2_HCEN;
	/*
@@ -512,7 +511,7 @@ static irqreturn_t das800_interrupt(int irq, void *d)
			val >>= 4;	/* 12-bit sample */

		/* if there are more data points to collect */
		if (devpriv->count > 0 || devpriv->forever) {
		if (cmd->stop_src == TRIG_NONE || devpriv->count > 0) {
			/* write data point to buffer */
			cfc_write_to_buffer(s, val & s->maxdata);
			devpriv->count--;
@@ -527,7 +526,7 @@ static irqreturn_t das800_interrupt(int irq, void *d)
		return IRQ_HANDLED;
	}

	if (devpriv->count > 0 || devpriv->forever) {
	if (cmd->stop_src == TRIG_NONE || devpriv->count > 0) {
		/* Re-enable card's interrupt.
		 * We already have spinlock, so indirect addressing is safe */
		das800_ind_write(dev, CONTROL1_INTE | devpriv->do_bits,