Doc: dm raid: Fix typo in dm-raid.txt



This patch fix spelling typos in Documentation/device-mapper/dm-raid.txt.

Signed-off-by: default avatarMasanari Iida <standby24x7@gmail.com>
Signed-off-by: default avatarJonathan Corbet <corbet@lwn.net>
parent 7058763b
Loading
Loading
Loading
Loading
+4 −4
Original line number Diff line number Diff line
@@ -17,7 +17,7 @@ The target is named "raid" and it accepts the following parameters:
  raid0		RAID0 striping (no resilience)
  raid1		RAID1 mirroring
  raid4		RAID4 with dedicated last parity disk
  raid5_n 	RAID5 with dedicated last parity disk suporting takeover
  raid5_n 	RAID5 with dedicated last parity disk supporting takeover
		Same as raid4
		-Transitory layout
  raid5_la	RAID5 left asymmetric
@@ -36,7 +36,7 @@ The target is named "raid" and it accepts the following parameters:
		- rotating parity N (right-to-left) with data continuation
  raid6_n_6	RAID6 with dedicate parity disks
		- parity and Q-syndrome on the last 2 disks;
		  laylout for takeover from/to raid4/raid5_n
		  layout for takeover from/to raid4/raid5_n
  raid6_la_6	Same as "raid_la" plus dedicated last Q-syndrome disk
		- layout for takeover from raid5_la from/to raid6
  raid6_ra_6	Same as "raid5_ra" dedicated last Q-syndrome disk
@@ -137,8 +137,8 @@ The target is named "raid" and it accepts the following parameters:
		device removal (negative value) or device addition (positive
		value) to any reshape supporting raid levels 4/5/6 and 10.
		RAID levels 4/5/6 allow for addition of devices (metadata
		and data device tupel), raid10_near and raid10_offset only
		allow for device addtion. raid10_far does not support any
		and data device tuple), raid10_near and raid10_offset only
		allow for device addition. raid10_far does not support any
		reshaping at all.
		A minimum of devices have to be kept to enforce resilience,
		which is 3 devices for raid4/5 and 4 devices for raid6.