Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Commit 1f153093 authored by Niklas Söderlund's avatar Niklas Söderlund Committed by Simon Horman
Browse files

arm64: dts: renesas: r8a7796: decrease temperature hysteresis



To incorporate more tests by the hardware team decrease the hysteresis
value to 1C.

Signed-off-by: default avatarNiklas Söderlund <niklas.soderlund+renesas@ragnatech.se>
Signed-off-by: default avatarSimon Horman <horms+renesas@verge.net.au>
parent 02f15e4b
Loading
Loading
Loading
Loading
+6 −6
Original line number Diff line number Diff line
@@ -2072,12 +2072,12 @@
			trips {
				sensor1_passive: sensor1-passive {
					temperature = <95000>;
					hysteresis = <2000>;
					hysteresis = <1000>;
					type = "passive";
				};
				sensor1_crit: sensor1-crit {
					temperature = <120000>;
					hysteresis = <2000>;
					hysteresis = <1000>;
					type = "critical";
				};
			};
@@ -2098,12 +2098,12 @@
			trips {
				sensor2_passive: sensor2-passive {
					temperature = <95000>;
					hysteresis = <2000>;
					hysteresis = <1000>;
					type = "passive";
				};
				sensor2_crit: sensor2-crit {
					temperature = <120000>;
					hysteresis = <2000>;
					hysteresis = <1000>;
					type = "critical";
				};
			};
@@ -2124,12 +2124,12 @@
			trips {
				sensor3_passive: sensor3-passive {
					temperature = <95000>;
					hysteresis = <2000>;
					hysteresis = <1000>;
					type = "passive";
				};
				sensor3_crit: sensor3-crit {
					temperature = <120000>;
					hysteresis = <2000>;
					hysteresis = <1000>;
					type = "critical";
				};
			};