Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Commit ffcaade3 authored by Stefan Richter's avatar Stefan Richter
Browse files

firewire: fw-sbp2: fix spindown for PL-3507 and TSB42AA9 firmwares



Reported by Tino Keitel:  PL-3507 with firmware from Prolific does not
spin down the disk on START STOP UNIT with power condition = 0 and start
= 0.  It does however work with power condition = 2 or 3.

Also found while investigating this:  DViCO Momobay CX-1 and FX-3A (TI
TSB42AA9/A based) become unresponsive after START STOP UNIT with power
condition = 0 and start = 0.  They stay responsive if power condition is
set when stopping the motor.

Signed-off-by: default avatarStefan Richter <stefanr@s5r6.in-berlin.de>
Tested-by: default avatarTino Keitel <tino.keitel@gmx.de>
parent d2886ea3
Loading
Loading
Loading
Loading
+20 −2
Original line number Diff line number Diff line
@@ -86,6 +86,11 @@ MODULE_PARM_DESC(exclusive_login, "Exclusive login to sbp2 device "
 * - delay inquiry
 *   Wait extra SBP2_INQUIRY_DELAY seconds after login before SCSI inquiry.
 *
 * - power condition
 *   Set the power condition field in the START STOP UNIT commands sent by
 *   sd_mod on suspend, resume, and shutdown (if manage_start_stop is on).
 *   Some disks need this to spin down or to resume properly.
 *
 * - override internal blacklist
 *   Instead of adding to the built-in blacklist, use only the workarounds
 *   specified in the module load parameter.
@@ -97,6 +102,7 @@ MODULE_PARM_DESC(exclusive_login, "Exclusive login to sbp2 device "
#define SBP2_WORKAROUND_FIX_CAPACITY	0x8
#define SBP2_WORKAROUND_DELAY_INQUIRY	0x10
#define SBP2_INQUIRY_DELAY		12
#define SBP2_WORKAROUND_POWER_CONDITION	0x20
#define SBP2_WORKAROUND_OVERRIDE	0x100

static int sbp2_param_workarounds;
@@ -107,6 +113,8 @@ MODULE_PARM_DESC(workarounds, "Work around device bugs (default = 0"
	", skip mode page 8 = "   __stringify(SBP2_WORKAROUND_MODE_SENSE_8)
	", fix capacity = "       __stringify(SBP2_WORKAROUND_FIX_CAPACITY)
	", delay inquiry = "      __stringify(SBP2_WORKAROUND_DELAY_INQUIRY)
	", set power condition in start stop unit = "
				  __stringify(SBP2_WORKAROUND_POWER_CONDITION)
	", override internal blacklist = " __stringify(SBP2_WORKAROUND_OVERRIDE)
	", or a combination)");

@@ -310,18 +318,25 @@ static const struct {
		.firmware_revision	= 0x002800,
		.model			= 0x001010,
		.workarounds		= SBP2_WORKAROUND_INQUIRY_36 |
					  SBP2_WORKAROUND_MODE_SENSE_8,
					  SBP2_WORKAROUND_MODE_SENSE_8 |
					  SBP2_WORKAROUND_POWER_CONDITION,
	},
	/* DViCO Momobay FX-3A with TSB42AA9A bridge */ {
		.firmware_revision	= 0x002800,
		.model			= 0x000000,
		.workarounds		= SBP2_WORKAROUND_DELAY_INQUIRY,
		.workarounds		= SBP2_WORKAROUND_DELAY_INQUIRY |
					  SBP2_WORKAROUND_POWER_CONDITION,
	},
	/* Initio bridges, actually only needed for some older ones */ {
		.firmware_revision	= 0x000200,
		.model			= ~0,
		.workarounds		= SBP2_WORKAROUND_INQUIRY_36,
	},
	/* PL-3507 bridge with Prolific firmware */ {
		.firmware_revision	= 0x012800,
		.model			= ~0,
		.workarounds		= SBP2_WORKAROUND_POWER_CONDITION,
	},
	/* Symbios bridge */ {
		.firmware_revision	= 0xa0b800,
		.model			= ~0,
@@ -1540,6 +1555,9 @@ static int sbp2_scsi_slave_configure(struct scsi_device *sdev)
	if (lu->tgt->workarounds & SBP2_WORKAROUND_FIX_CAPACITY)
		sdev->fix_capacity = 1;

	if (lu->tgt->workarounds & SBP2_WORKAROUND_POWER_CONDITION)
		sdev->start_stop_pwr_cond = 1;

	if (lu->tgt->workarounds & SBP2_WORKAROUND_128K_MAX_TRANS)
		blk_queue_max_sectors(sdev->request_queue, 128 * 1024 / 512);